Start And Stop load Wiring

Start & Stop Load wiring:

This circuit diagram shows the Start And Stop Wiring Diagram. In this circuit, we use a DP MCB ( Double Pole Minature Circuit ), a magnetic contactor, a SP MCB ( Single Pole Minature Circuit Breaker ), an start switch, an stop switch. This circuit is very simple and easy to make. If you want to know more about this circuit please check our youtube video below the post. For more learning please stay with us.

Diagram of Output control wiring:

Start And Stop load Wiring
Fig 1: Start And Stop load Wiring

Components Need for this Project:

You can get the components from any of the sites below:

  1. DP MCB [See Buy Click Amazon]
  2. SP MCB [See Buy Click Amazon]
  3. Contactor   [See Buy Click Amazon]
  4. Start Switch  [See Buy Click Amazon]
  5. Stop Switch [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the Output control wiring:

01. DP MCB

DP MCB
Fig 2: DP MCB


Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.

02. SP MCB

SP MCB
Fig 3: SP MCB


MCB SP means single pole it protects only one phase switching. MCB (Miniature Circuit Breaker) Curswitch is the most basic general-purpose switch that you use to control a light or another device from one location. These Switches Have Two Brass-Colored Screw Terminals Connected to the hot Power Source Wires. (MCB) For any Distribution Board, the Protection System Must be Used in The Incomer. Phase and Neutral Single Phase Supply to break. 120-volt circuits, 15-20 amp single pole breaker is typically used.

03. Contactor  

Contactor
Fig 4: Contactor


A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

04. Start Switch

Start Switch
Fig 5: Start Switch


The operator switch has its contact in Normally Open condition. To make Ladder Logic you need to understand NO contact. A Classic Switch has one Input And one Output. In "No Switch," YoungBoy Raps About Ammunition, Murder, Firearms, and Firearm Attachments Such as a Switch. The contact of the switch whose contact is already open is NO. That is enough to understand. no switch in a circuit, then the circuit will not function as intended. to write a program such that when the red light is on, This switch is now in normally open condition. When you push the switch it will close and the red light will turn on.

05. Stop Switch

Stop Switch
Fig 6: Stop Switch


Indicates the contacts of switches or automatic actionable devices. Simply put, the push switches, magnetic contactors, and relays that we use in the factory Normally have Close Contact exists. At this moment the switch will be in normally closed condition. Because already he is sitting close. When turned off the contact will open. To make ladder logic you need to understand NC contact. As already explained. The switch contact is already closed in NC. That is enough to understand.

Thank You for visiting the website. Keep visiting for more Updates.