Contactor With Timer Wiring

Contactor with Timer wiring:

This diagram shows how to make Contactor With Timer Wiring. In this circuit, we use a timer, a relay, a stop switch, a start switch, two magnetic contactors, a TP MCB ( Tripple Pole Miniature Circuit Breaker ), and a DP MCB ( Double Pole Miniature Circuit Breaker ). Now we need to connect all components very professionally like our diagram. 

Diagram of Contactor with timer wiring:

Contactor With Timer Wiring
Fig 1: Contactor With Timer Wiring

Components Need for this Project:

You can get the components from any of the sites below:

  1. DP MCB [See Buy Click Amazon]
  2. TP MCB  [See Buy Click Amazon]
  3. Relay  [See Buy Click Amazon]
  4. Timer  [See Buy Click Amazon]
  5. NO Switch [See Buy Click Amazon]
  6. NC Switch [See Buy Click Amazon]
  7. Contactor [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the Contactor with timer wiring:

01. DP MCB

DP MCB
Fig 2: DP MCB


Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.

02. TP MCB

TP MCB
Fig 3: TP MCB


Three wires can be controlled by a triple pole MCB. Triple pole MCB circuit breakers are generally used in three-phase lines. A triple-pole MCB circuit breaker has three wires at its input and three wires at its output. But one can use this circuit breaker in a single-phase line. TP MCB widely used in industries. The reason is that it has three poles. And this TP circuit breaker is used to provide three-phase and three-phase connections. A neutral is not normally used in three-phase lines. But a 4-pole MCB circuit breaker is used if needed.

03. Relay  

Relay
Fig 4: Relay


This relay is known as 8 pin relay because it has 8 terminals. When coil power is supplied. A magnetic induction is created due to which the connected sheet of the Com part moves towards the NO part changing to NO-NC. The former NC region loses conductivity and becomes NO. Thus, as long as power is supplied to the coil, the NO and NC positions will remain in the alternating state, and when the power is removed from the coil, it will return to its original position. This is basically how a relay switch works.

04. Timer  

Timer
Fig 5: Timer


Timer is a specialized type of clock used for measuring specific time intervals.An electromechanical cam timer uses a small synchronous AC motor turning a cam against a comb of switch contacts. This type of timer often has a friction clutch between the gear train and the cam, the cam can be turned to reset the time.A simple example of the first type is an hourglass. Working method timers have two main groups: hardware and software timers.Most timers give an indication that the time interval that had been set has expired.

05. NO Switch

NO Switch
Fig 6: NO Switch


The operator switch has its contact in Normally Open condition. To make Ladder Logic you need to understand NO contact. A Classic Switch has one Input And one Output. In "No Switch," YoungBoy Raps About Ammunition, Murder, Firearms, and Firearm Attachments Such as a Switch. The contact of the switch whose contact is already open is NO. That is enough to understand. no switch in a circuit, then the circuit will not function as intended. to write a program such that when the red light is on, This switch is now in normally open condition. When you push the switch it will close and the red light will turn on.

06. NC Switch

NC Switch
Fig 7: NC Switch


Indicates the contacts of switches or automatic actionable devices. Simply put, the push switches, magnetic contactors, and relays that we use in the factory Normally have Close Contact exists. At this moment the switch will be in normally closed condition. Because already he is sitting close. When turned off the contact will open. To make ladder logic you need to understand NC contact. As already explained. The switch contact is already closed in NC. That is enough to understand.

07. Contactor

Contactor
Fig 8: Contactor


A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

Thank You for visiting the website. Keep visiting for more Updates.