3 Phase motor wiring diagram:
This diagram shows how to make 3 phase motor wiring diagram. In this circuit, we use MCCB ( Molded Case Circuit Breaker ), a voltage control, a magnetic contactor, an overload, a start switch, a stop switch, and a 3-phase water pump motor. Here we need to connect all components like our circuit diagrma. Then it will be ready for use.
Diagram of 3 phase motor wiring:
Components Need for this Project:
You can get the components from any of the sites below:
- MCCB [See Buy Click Amazon]
- Magnetic Contactor [See Buy Click Amazon]
- Overload [See Buy Click Amazon]
- Voltage Control [See Buy Click Amazon]
- Start Switch [See Buy Click Amazon]
- Stop Switch [See Buy Click Amazon]
- 3 Phase Motor [See Buy Click Amazon]
Read Also:
Components used to make the 3 phase motor diagram:
01. MCCB
Fig 2: MCCB |
MCCB (Molded Case Circuit Breakers) is a Required Component of Electrical Systems, Providing Overload Protection And Short-Circuit Protection. Circuit breakers are electrical devices that offer protection against fault currents. Molded Case Circuit Breakers (MCCB) or Molded Case Circuit Breakers Use air as The Dielectric Medium to Break a Circuit. Air Has a Low Dielectric Strength as Opposed to Other Mediums Which is why it is Used for Protection in low-Voltage Circuits. In Most Cases, Molded Case Circuit Breakers are installed in the Main Power Distribution Board of a Facility, Allowing the system to be easily shut Down When Necessary.
02. Magnetic ContactorÂ
Fig 3: Magnetic Contactor |
A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)
03. OverloadÂ
Fig 4: Overload |
 Overload relays are often used to protect the motor from excessive current flow. Overload relays are used to protect the motor from overheating. Besides some specific faults such as phase to phase, phase to ground, etc. overload relay provides protection to the motor. A thermal overload relay works on the principle of bimetallic strip electro-thermal characteristics. When the bimetallic heats up, the trip function in the overload relay turns on and disconnects the power supply to the contactor coil, thus tripping the overload relay and breaking the motor current and saving the motor.
04. Voltage Control Â
Fig 5: Voltage Control |
A voltage protector device, also called a lightning arrester, is an electronic device that provides voltage to various electronic devices, appliances and communication lines. When an external interference causes a sudden current or voltage to be generated in an electrical circuit or communication line, the voltage protector can be used for a very short period of time. Within the shunt operating voltage protection device VPD name is also increased Argestor, all amplifier protectors intended for specific purposes are actually a type of quick switch and the sequence protector is activated within a certain voltage range. After activation, the suppression element of the sequence protector will be disconnected from the high-impedance state and the L pole will transition to a low-impedance state.
05. Start Switch
Fig 6: Start Switch |
The operator switch has its contact in Normally Open condition. To make Ladder Logic you need to understand NO contact. A Classic Switch has one Input And one Output. In "No Switch," YoungBoy Raps About Ammunition, Murder, Firearms, and Firearm Attachments Such as a Switch. The contact of the switch whose contact is already open is NO. That is enough to understand. no switch in a circuit, then the circuit will not function as intended. to write a program such that when the red light is on, This switch is now in normally open condition. When you push the switch it will close and the red light will turn on.
06. Stop Switch
Fig 7: Stop Switch |
 Indicates the contacts of switches or automatic actionable devices. Simply put, the push switches, magnetic contactors, and relays that we use in the factory Normally have Close Contact exists. At this moment the switch will be in normally closed condition. Because already he is sitting close. When turned off the contact will open. To make ladder logic you need to understand NC contact. As already explained. The switch contact is already closed in NC. That is enough to understand.
07. 3 Phase Motor
Fig 8: 3 Phase Motor |
A Three-Phase Motor is an Electric Motor That Typically Receives its Power From a Three-Phase System (three-phase current) This can be realized via a Three-Phase Mains Supply or a Frequency Inverter. Three-Phase Motors are Available as Synchronous and Asynchronous Motors. Three Phase Alternating Current Power Motor is Economical to Supply Power to the data Center Since it Requires Less Conductor Material to Supply Electricity. This Explains Why 3 Phase Alternating Current Motor is Used in Electric Transmission, Generation, and Distribution in Most Countries Worldwide.
Thank You for visiting the website. Keep visiting for more Updates.