3 Phase Motor Starter Start Wiring

3 Phase Motor Starter Start wiring:

This diagram shows how to make 3 Phase Motor Starter Start Wiring. In this circuit, we use a TP MCB ( Tripple Pole Minature Circuit Breaker ), a DP MCB ( Double Pole Minature Circuit Breaker ), a stop switch, a start switch, a magnetic contactor, and a 3-phase motor. Now we need to connect all components like our diagram.

Diagram of 3 Phase motor starter wiring:

3 Phase Motor Starter Start Wiring
Fig 1: 3 Phase Motor Starter Start Wiring

Components Need for this Project:

You can get the components from any of the sites below:

  1. TP MCB [See Buy Click Amazon]
  2. DP MCB [See Buy Click Amazon]
  3. Contactor  [See Buy Click Amazon]
  4. Stop Switch  [See Buy Click Amazon]
  5. Start Switch  [See Buy Click Amazon]
  6. 3 Phase Motor  [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the 3 Phase motor wiring:

01. TP MCB

TP MCB
Fig 2: TP MCB


Three wires can be controlled by a triple pole MCB. Triple pole MCB circuit breakers are generally used in three-phase lines. A triple-pole MCB circuit breaker has three wires at its input and three wires at its output. But one can use this circuit breaker in a single-phase line. TP MCB widely used in industries. The reason is that it has three poles. And this TP circuit breaker is used to provide three-phase and three-phase connections. A neutral is not normally used in three-phase lines. But a 4-pole MCB circuit breaker is used if needed.

02. DP MCB

DP MCB
Fig 3: DP MCB


Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.

03. Contactor 

Contactor
Fig 4: Contactor


 A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

04. Stop Switch

Stop Switch
Fig 5: Stop Switch


Indicates the contacts of switches or automatic actionable devices. Simply put, the push switches, magnetic contactors, and relays that we use in the factory Normally have Close Contact exists. At this moment the switch will be in normally closed condition. Because already he is sitting close. When turned off the contact will open. To make ladder logic you need to understand NC contact. As already explained. The switch contact is already closed in NC. That is enough to understand.

05. Start Switch

Start Switch
Fig 6: Start Switch


The operator switch has its contact in Normally Open condition. To make Ladder Logic you need to understand NO contact. A Classic Switch has one Input And one Output. In "No Switch," YoungBoy Raps About Ammunition, Murder, Firearms, and Firearm Attachments Such as a Switch. The contact of the switch whose contact is already open is NO. That is enough to understand. no switch in a circuit, then the circuit will not function as intended. to write a program such that when the red light is on, This switch is now in normally open condition. When you push the switch it will close and the red light will turn on.

06. 3 Phase Motor

3 Phase Motor
Fig 7: 3 Phase Motor


A Three-Phase Motor is an Electric Motor That Typically Receives its Power From a Three-Phase System (three-phase current) This can be realized via a Three-Phase Mains Supply or a Frequency Inverter. Three-Phase Motors are Available as Synchronous and Asynchronous Motors. Three Phase Alternating Current Power Motor is Economical to Supply Power to the data Center Since it Requires Less Conductor Material to Supply Electricity. This Explains Why 3 Phase Alternating Current Motor is Used in Electric Transmission, Generation, and Distribution in Most Countries Worldwide.

Thank You for visiting the website. Keep visiting for more Updates.

Post a Comment

Do leave your comments

Previous Post Next Post

Advertisements

Advertisements

Blogging Experiment
Electronic Experiment Subscribe our Youtube Channel
Subscribe