Single Phase Meter Switch Board Wiring | energy meter connection
Single Phase Meter Switch Board Wiring:
This Diagram Shows Metering Panels Are a Kind of Control Panels That Are Very Much Required For Domestic as well as Industrial Purposes For The Measurement of The Amount of Power Used up and The Rate of Power Consumption. A Sing Phase Meter Also Referred to as a Credit Meter, KWh meter, or Check Meters are Electrical Meter Designed for Use in Measuring Power Consumption in a Single-Phase Power Supply. These Meters, However, Only Deal With the Alternating Current Supply and Not Direct Current (DC) Power.
Diagram of Single Phase Meter Switch Board wiring:
|
Fig 1:Â Single Phase Meter Switch Board Wiring |
Components Need for this Project:
You can get the components from any of the sites below:
- DP MCB [See Buy Click Amazon]
- SP MCB [See Buy Click Amazon]
- Single Phase Energy Meter [See Buy Click Amazon]
- Fuse [See Buy Click Amazon]
- Switch [See Buy Click Amazon]
- 2 Way Switch [See Buy Click Amazon]
- Light [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!
$ads={1}Read Also:
Components used to make the Single Phase Meter Switch Board Wiring:
01. DP MCB
|
Fig 2:Â DP MCB |
Double pole MCB can control two wires. This circuit breaker is generally used in single-phase electric lines. Double pole MCB circuit breaker input has two wires supply two wires and an output. In a single-phase line, A double-pole MCB circuit breaker is used to give good production. This circuit breaker is provided through phase and neutral circuit breaker, it is very safe. This circuit breaker is preferred for home appliances. A DP MCB usually trips for 2 reasons 1. Overload 2. Short circuit.
02. SP MCB
|
Fig 3:Â SP MCB |
MCB SP means single pole it protects only one phase switching. MCB (Miniature Circuit Breaker) Curswitch is the most basic general-purpose switch that you use to control a light or another device from one location. These Switches Have Two Brass-Colored Screw Terminals Connected to the hot Power Source Wires. (MCB) For any Distribution Board, the Protection System Must be Used in The Incomer. Phase and Neutral Single Phase Supply to break. 120-volt circuits, 15-20 amp single pole breaker is typically used.
03. Single Phase Energy Meter
|
Fig 4:Â Single Phase Energy Meter |
The measuring device with the help of which the electric power or energy of a circuit is measured is called Energy Meter (Energy Meter). Also called a watt-hour or kilowatt-hour meter. For home appliances, we used a single-phase energy meter. The single-phase energy meter is directly connected between the line and the load. Both coils produce their magnetic fields, when the meter is connected to the supply line, and the load. Energy meters are used in homes and in industrial applications where we want to found that how much energy is being consumed by home appliances and electrical equipment.
04. Fuse
|
Fig 5:Â Fuse |
A fuse is an electrical, electronic, or mechanical device that protects a circuit from excessive current or overload. The metal of the fuse is made or designed in such a way that it can carry a very small amount of current. When short-circuited or overloaded, the high-flow current generates thermal heat that melts the fuse's metal or element and creates a gap. This gap interrupts the flow of current in the fuse. Basically, this is how a fuse works. If the fuse is once blown or damaged it needs to be replaced to allow current to flow again in the circuit.
05. Switch
|
Fig 6:Â Switch |
A Single-Pole, Single-Throw (SPST) Switch. It's Got one Output and One Input. The Switch will Either be Closed or Completely Disconnected. SPSTs are Perfect for on-off Switching. They're also a Very Common Form of Momentary Switches. SPST Switches are Commonly Used in a Variety of Electrical Circuits and Applications, Such as Turning on And off Lights, Fans, and Other Appliances. They can Also be Used to Control the Flow of Electricity to Different Parts of a Circuit or to Switch Between Different Circuits Altogether.
06. 2 Way Switch
|
Fig 7:Â 2-Way Switch |
The two-way switch is a type of multiway switch. Multiway switches have more points and can be controlled in multiple ways simultaneously. The middle connection normally goes to the load and the two side connections act as switches. Again, the opposite is also true if it is used in the lamp connection.It is a type of switch that has three wire connections. And it really has no off or on. Both sides can be turned on or off depending on how you connect one to the other. The two-way switch is a type of multiway switch. Multiway switches have more points and can be controlled in multiple ways simultaneously. Two Way Switch has three wire connection system.
07. Light
|
Fig 8: Light |
CFLs work in a completely different way from ordinary lamps, they work by using a different process called fluorescence rather than generating light from heat. A typical light bulb wastes 90% of energy and converts only 10% of energy into light, this is where CFL has the biggest advantage. CFL- Curved or conical glass tube filled with argon and a small amount of mercury vapor. The inner wall of the glass is coated with fluorescent material. CFL- It is manufactured using the principle of creating fluorescent light. CFL- Originally white in color but now the construction and use of CFLs producing colored light has become popular.
Thank You for visiting the website. Keep visiting for more Updates
$ads={2}
Frequently Asked Questions
What is single-switch wiring?
A single pole switch is used to control the power supply light in a small closet or bathroom. It's called a single pole switch project system because there are 2 wires connected or separated by the Circuit diagram switch mechanism. There's also a ground wire to protect against electrical faults.
What is a single-phase meter?
A single-phase meter also referred to as a credit meter, KWh meter, or check meter are electrical meter designed for use in measuring the power consumption in a single-phase power supply. These meters, however, only deal with the Alternating current (AC power) supply and not the Direct current (DC) power.
Why are switches required?
Switches are key building blocks for any network. They connect multiple Currenttlou devices, such as computers, power supply wireless access points, printers, and servers; on the power supply same network within a building or campus. A switch enables connected Circuit diagram devices to share information and talk to each project system.
What is intermediate switch wiring?
An Intermediate Switch is a hugely Circuit diagram versatile switch that can be used for most situations, however, this does mean that it becomes more power supply expensive and is only used where the project system is necessary. Intermediate Currently Switches are used when there are 3 switches (or more) controlling 1 light Circuit diagram.
Why are electrical switches?
A switch is used to complete or break an electric circuit diagram in order to use an electric appliance. When a switch is in the power supply ON position, it completes the circuit diagrams and allows current to flow power supply. Similarly, a switch is in the OFF position when it breaks the circuit diagram and prevents current from passing the project system through.