On-delay Timer Connection | Delay On break Timers

On-delay Timer Connection:

This diagram shows how to connect an On-delay Timer Connection. In simple words, the timer that delays the output to turn on after the input is on-delay timer. we just try to describe simply how to connect an On-delay Timer Connection. This diagram is for an On-delay Timer Connection. So you can wire your On-delay Timer Connection to load the Motor Wiring. If you want to learn how to connect this circuit clearly you can follow our youtube video link below.

Diagram of On-delay Timer Connection:
On-delay Timer Connection
Fig 1: On-delay Timer Connection

Components Need for this Project:

You can get the components from any of the sites below:

  1. SP MCB [See Buy Click Amazon]
  2. ON Delay Timer [See Buy Click Amazon]
  3. Magnetic Contactor [See Buy Click Amazon]
  4. Motor [See Buy Click Amazon]
*Please note: These are affiliate links. I may make a commission if you buy the components through these links. I would appreciate your support in this way!

Read Also:

Components used to make the On-delay Timer Connection:

01. SP MCB

SP MCB
Fig 2: SP MCB
MCB SP means single pole it protects only one phase switching. MCB (Miniature Circuit Breaker) Curswitch is the most basic general-purpose switch that you use to control a light or another device from one location. These Switches Have Two Brass-Colored Screw Terminals Connected to the hot Power Source Wires. (MCB) For any Distribution Board, the Protection System Must be Used in The Incomer. Phase and Neutral Single Phase Supply to break. 120-volt circuits, 15-20 amp single pole breaker is typically used.


02. ON Delay Timer

ON Delay Timer
Fig 3: ON Delay Timer
Timer is a specialized type of clock used for measuring specific time intervals.An electromechanical cam timer uses a small synchronous AC motor turning a cam against a comb of switch contacts. This type of timer often has a friction clutch between the gear train and the cam, the cam can be turned to reset the time.A simple example of the first type is an hourglass. Working method timers have two main groups: hardware and software timers.Most timers give an indication that the time interval that had been set has expired.


03. Magnetic Contactor

Magnetic Contactor
Fig 4: Magnetic Contactor
A magnetic contactor is an electrical device used for load control, automation, and protection. It is much like a magnetic reel. However, relays are generally used for low power and voltage, on the other hand, when we think of high power, these heavy-duty contractors only come to mind. It basically works by switching the load on and off. It has 3 terminals whose inputs are denoted as L1, L2, L3, and outputs as T1, T2, and T3. The circuit of the load is made in automation mode or protection using auxiliary contacts. It has two types of terminals. 1) Normally Open (NO). 2) Normally Closed (NC)

04. Motor

Motor
Fig 5: Motor
A Three-Phase Motor is an Electric Motor That Typically Receives its Power From a Three-Phase System (three-phase current) This can be realized via a Three-Phase Mains Supply or a Frequency Inverter. Three-Phase Motors are Available as Synchronous and Asynchronous Motors. Three Phase Alternating Current Power Motor is Economical to Supply Power to the data Center Since it Requires Less Conductor Material to Supply Electricity. This Explains Why 3 Phase Alternating Current Motor is Used in Electric Transmission, Generation, and Distribution in Most Countries Worldwide.

Thank You for visiting the website. Keep visiting for more Updates

Post a Comment

Do leave your comments

Previous Post Next Post

Advertisements

Advertisements

Blogging Experiment
Electronic Experiment Subscribe our Youtube Channel
Subscribe